Serv_ max_wattage_Report No. : NEU_FT_4116_01_001
Wattage at highest mode is 700W and the observed wattage for the highest mode (Mode 2 ) is 705W .
Test Environment: 28°C, 74% RH.
Data reported by Neutopia Quality Testing and Inspection Lab.
Serv_ max_Boiling time_Report No. : NEU_FT_4116_01_001
Time to boil rated capacity (1.3L) of water at highest mode (mode 2 ) is 10min and the observed time is 9min. 52 sec. Also , Time to boil rated capacity (1.3L) of water at lowest mode (mode 1 ) is 20min. And the observed time is 22min. 10 sec.
Test Environment: 30°C, 68% RH.
Data reported by Neutopia Quality Testing and Inspection Lab.
Serv_ max_Dry boil Protection_Report No. : NEU_FT_4116_01_001
The time taken to cut off at dry boil is 40 sec. And the observed time for the cut off is 46 sec.
Test Environment: 26°C, 78% RH.
Data reported by Neutopia Quality Testing and Inspection Lab.
Serv_ max_Leakage current Test_Report No. : NEU_FT_4116_01_001
For portable class I appliances leakage current should be less than 0.21 mA and the observed leakage current is 0.0429 mA.
Test Environment: 28°C, 81% RH.
Data reported by Neutopia Quality Testing and Inspection Lab.
Serv_ max_Insulation resistance Test_Report No. : NEU_FT_4116_01_001
Insulation resistance should be ≥ 2 MΩ and the observed insulation resistance is 4.5GΩ.
Test Environment: 25°C, 80% RH.
Data reported by Neutopia Quality Testing and Inspection Lab.
Serv_ max_High voltage test_Report No. : NEU_FT_4116_01_001
Applied 1250V AC for 1 min . There must be No breakdown , No Collapse of the applied voltage and no insulation puncture and the observation for the Serv max. Is the same .
Test Environment: 28°C, 84% RH.
Data reported by Neutopia Quality Testing and Inspection Lab.
Serv_ max_Temp. Rise test_Report No. : NEU_FT_4116_01_001
Temp. rise should be Temperature rise should not exceed above ambient .
i) 35°C on handle,
ii) 45°C on Switch
iii) 50°C external body
And the observed Temp. rise is
i) 3.2°C on handle,
ii) 11°C on Switch
iii) 24.3°C external body
Test Environment: 32°C, 72% RH.
Data reported by Neutopia Quality Testing and Inspection Lab.
Serv_ max_Thermal efficiency_Report No. : NEU_FT_4116_01_001
Thermal efficiency Should be≥ 90% and the observed Thermal efficiency is 85.21%.
Test Environment: 31°C, 76% RH.
Data reported by Neutopia Quality Testing and Inspection Lab.
Serv_ max_weight_Report No. : NEU_FT_4116_01_001
Product weight of the Serv max. Is 825g and the observed weight is 823g.
Test Environment: 29°C, 68% RH.
Data reported by Neutopia Quality Testing and Inspection Lab.
Serv_ max_Dimension_Report No. : NEU_FT_4116_01_001
Product dimension of the Serv max. Is (188*230*193)mm and the observed dimension is (188*225*195)mm.
Test Environment: 27°C, 70% RH.
Data reported by Neutopia Quality Testing and Inspection Lab.